Scaffold
|
The safety cap is firmly clamped to ensure stable position in the test and can be moved to adjust the distance between the helmet and the flame ejector head.
|
Timer
|
The indication error is ± 1%, which is used to record the continuous ignition time and be accurate to 0.01s
|
Timer
|
The indication error is ± 1%. It is used to determine the time when the flame is applied to the safety helmet, and it can set the combustion time by itself. After the flame is finished, the Bunsen lamp can move itself, and the ignition time range is 0-999.9 seconds.
|
Flame height measuring device
|
High 50mm
|
Flamethrower
|
Horizontally placed fuel nozzle, internal diameter 10mm
|
Fuel supply device
|
Pressure regulating valve, air quantity regulating valve, gas storage tank device, can guarantee the flame jet head to spray 50mm length blue flame steadily
|
Box
|
A large enough box to ensure that the test is not affected by the wind
|
Power supply voltage and power
|
220V±10% 50HZ,Power about: 100W
|
Inner diameter of the lamp
|
10mm±0.10mm
|
Gas source
|
Methane, propane, butane, liquefied petroleum gas
|
Ambient temperature
|
—10℃—30℃
|
Relative humidity
|
≤85%
|